3001 Drywell Calibrator~
  • For checking the accuracy of thermometers & probes
  • 0.1°C resolution - small & lightweight
  • Traceable certificate of calibration included
  • Range +33 to +300°C
  • Well depth of 100mm
  • Accepts 3.3mm, 4.1mm, 4.8mm, 6.4mm 9.6mm probe
The 3001 dry-well is a small and lightweight heat source, ideal for checking the accuracy of digital thermometers and probes. The unit has a temperature range of +33 to +300°C with a resolution of 0.1°C. The 3001 has a high level of stability (±0.5°C) and a stabilisation time of five minutes. Plug it in, switch it on, set the verification temperature with the front panel buttons and insert your probe into the correct size well. Compare the temperature reading of your thermometer to the display and the difference is the error. The 3001 will accept probe diameter sizes, Ø3.3, 4, 4.76 and 6.35mm.

Specification 3001 Dry-Well
Range +33 to +300°C
Resolution 0.1°C
Accuracy ± 0.5°C (+33 to +199°C) & ± 1°C (+200 to +300°C)
Heating Time ambient to +300°C after 10 minutes
Well Depth 100mm
Power 230 Vac
Dimensions 57 x 125 x 158mm
Weight 900 grams
~705 Loop Calibrator
  • Simultaneous mA and %
  • mA accuracy of 0.02%
  • Measure, source and simulate mA
  • Push button 25% steps for fast easy linearity checks
  • "Span Check" for fast confirmation of zero and span
  • Selectable slow ramp, fast ramp, and step function
  • 24 volt internal loop supply
  • 0 - 20 mA or 4 - 20 mA default start up modes
~3001 Drywell Calibrator|1948940127|~3736~3737~~
3101 Drywell Calibrator~
  • Portable sub zero temperature source
  • 0.1°C resolution with a ± 0.5°C accuracy
  • Free traceable certificate of calibration
  • Temperature range -10 to +110°C
  • Well depth of 100mm
  • Supplied with two alloy inserts
The 3101 dry-well features an easy to read LED display with a temperature range of -10 to +110°C, a resolutionof 0.1°C. Heating time ambient to +100°C and cooling time ambient to 0°C is 10 minutes for both.
The 3101 is excellent for checking the calibration of a wide range of instrumentation including digital thermometers and sensors that need calibration checks below ambient. The unit has two wells, both 13mm in diameter and will accept removable inserts for most sensor diameter sizes as follows: Ø3.3, 4.1, 4.8, 6.4 and 9.6mm. Supplied with two alloy inserts of the customer's choice.

3101 Dry-Well Specification
Range -10 to +110°C
Resolution 0.1°C
Accuracy ± 0.5°C (-10 to +99°C) & ± 1°C (-100 to +110°C)
Heating Time ambient to +100°C or ambient to 0°C after 10 minutes
Well Depth 100mm
Power 230 Vac
Dimensions 89 x 152 x 186mm
Weight 1,800 grams
~707 Loop Calibrator
  • Features of the Fluke 705
  • "Quick Click" detented rotary knob for one handed operation
  • Higher accuracy: 0.015%
  • Mains Voltage Input protection
  • 250 Ohm loop resistance for use with Hart instrumentation